The problem with mixed fleets
Few portfolios are built from one brand. A plant from 2016 runs one SCADA. The next was built by a different EPC with another vendor. A rooftop portfolio reports only to the inverter maker's portal. An acquisition brings a fourth system with its own naming. Each has its own screen, its own export, its own idea of what "energy today" means.
So the O&M team logs into five places every morning, exports five files, and stitches them together in Excel. It works until someone is on leave.
The answer is not to replace every SCADA. That is expensive, slow, and the SCADA is doing its real job of controlling and protecting the plant perfectly well. The answer is to take a copy of the data out of each system and bring it into one place.
Five ways to get the data out
Almost every plant can send data out by at least one of these routes. Which one you use depends on what the SCADA supports and what the plant owner's IT team will allow.
| Route | How it works | Freshness | Good for |
|---|---|---|---|
| Files over SFTP | The SCADA writes a CSV or Excel export to a folder; the receiver collects new files on a schedule | Each file's interval, often daily or hourly | Older SCADA, cautious IT teams, daily reporting |
| HTTPS push | The SCADA or a gateway posts CSV or JSON to a web address with a token | As often as it sends | Systems that can call out but not be called in |
| OPC UA | A client reads, or subscribes to, values on the SCADA's OPC UA server | Near real time | Modern SCADA, live monitoring and alerts |
| MQTT | A subscriber receives messages the SCADA publishes to a broker | Near real time | Gateways and IoT-style data loggers |
| Inverter cloud API | Calls to the inverter maker's cloud with an account the owner grants | Minutes, within the vendor's limits | Plants with no SCADA beyond the vendor portal |
Files over SFTP
The plainest route, and often the first one a plant can offer. Most SCADA systems can schedule an export. SFTP is encrypted and widely allowed through firewalls. The care is in the details. Only pick up a file once it has finished being written. Import each file exactly once. And spot a block whose file has not arrived, rather than reporting the plant as if that block made nothing.
HTTPS push
Some systems cannot be reached from outside, but can send data out. A push endpoint gives each plant its own address and token, and the plant posts its readings as they are ready. It suits sites where the owner will not open any inbound port.
OPC UA
OPC UA (IEC 62541) is the industrial standard for exchanging data between control systems. Many modern SCADA systems run an OPC UA server. A client can subscribe to the values it needs, such as export energy, irradiance and inverter status, and receive changes as they happen. OPC UA has security built in: encrypted, signed sessions with certificates. Use it. And map nodes explicitly, so that "Meter1.ExportkWh" is pinned to the right field and never guessed from a name.
MQTT
MQTT is a lightweight publish-subscribe protocol, standardised by OASIS. Data loggers and gateways publish readings to topics on a broker, and any authorised subscriber receives them. It is efficient over poor links. The things to handle are message bursts after a reconnect, duplicate messages, and topics whose payload format changes without warning.
Inverter cloud APIs
Large inverter makers run their own monitoring clouds, and several offer an API for third parties. Huawei FusionSolar has a Northbound API. Sungrow iSolarCloud has an OpenAPI. They are useful where the vendor portal is the only system at the plant. Read the vendor's documentation closely before you rely on one. These APIs typically limit how often you can call them. Some allow only one active session per account, so a second login can log out the owner's own tools. Ask for a dedicated, read-only account. And expect history to come in windows, not all at once.
What about Modbus and IEC 104?
Inside the plant, devices often talk Modbus TCP or IEC 60870-5-104 to the SCADA. These are field and control-centre protocols. Reading them directly means putting equipment on the plant network, which most owners rightly resist. It is usually better to let the SCADA collect from the field and send the data out by one of the routes above.
Making different sources agree
Getting the data in is half the work. The other half is making it mean the same thing whichever plant it came from.
- One interval grid. Bring everything onto the same interval, such as 5 or 15 minutes, so plants can be compared side by side.
- Units checked. One SCADA reports W, another kW, a third cumulative kWh. Check every source against the plant's capacity, so a factor-of-1,000 error is caught on day one.
- Clocks checked. Know each source's time zone and whether an interval is labelled by its start or its end. A one-hour shift moves the whole generation curve.
- Gaps kept as gaps. A missing value stays missing, never zero. Record the comms gap and mark the day as partial.
- Several sources per plant. A plant may have one block on one brand and an extension on another. Each source keeps its own capacity and dates, and the plant total is built from all of them.
- Never silently overwrite. If a second source disagrees with a figure already stored, flag it. Replacing it is a person's decision, recorded.
Security rules worth insisting on
- Read-only. The monitoring system takes data out. It never sends a command into the plant.
- Credentials for SCADA, SFTP and vendor clouds stored encrypted, per customer, and never shown back in full.
- Encrypted transport everywhere: SFTP, HTTPS, OPC UA with security on, MQTT over TLS.
- One connector failing never stops the others.
- A raw copy of what arrived, so any figure can be traced back to its source.
How to start
- List each plant with its SCADA or portal, and what it can export.
- Choose the simplest route that gives the freshness you need. Daily reporting is happy with daily files. Trip alerts need live data.
- Agree with the owner's IT team which direction traffic may flow.
- Connect one plant, compare a week of figures with the SCADA's own screen, then roll on.
Once the data is in one place, everything else in this blog becomes possible: monitoring, loss analysis and reports that build themselves.
Where HKDataCrest Solar fits
HKDataCrest Solar takes plant data today by SFTP file collection, HTTPS push (CSV or JSON), OPC UA and MQTT, all read-only and through the same import rules: units and clocks checked, gaps kept as gaps, nothing overwritten without an admin's choice. Credentials are stored encrypted. Direct connections to inverter makers' cloud APIs, such as Huawei FusionSolar and Sungrow iSolarCloud, are in development. See data connectors and monitoring.