What soiling is, and why it varies so much
Anything that settles on the glass and blocks light counts: dust, sand, pollen, bird droppings, soot from nearby roads or industry, ash from crop burning. The loss depends on the local environment, the tilt of the modules, the season and the rain. A plant in a dry, dusty area can lose noticeably more each week than one in a humid area with regular rain. The same plant can soil fast in a dry season and barely at all in a monsoon.
That variation is the whole problem. A fixed cleaning schedule set at commissioning will be too frequent in some months and too rare in others. The only way to get it right is to measure.
Three ways to measure soiling
1. A soiling station
A soiling station compares two identical reference devices, one cleaned regularly and one left to soil like the plant. The ratio between them is the soiling ratio. IEC 61724-1 describes soiling ratio measurement as part of PV performance monitoring.
It is direct and easy to understand. The limits: the station measures one spot, which may not soil like the whole plant; the clean device has to actually be cleaned on schedule; and it costs money to buy and maintain.
2. The plant's own performance ratio trend
This needs no extra hardware, only good data. Dust settles a little every day, so between cleanings the plant's daily PR slides down slowly. After a cleaning it jumps back up. Fit a line through the PRs between two cleanings and the slope is the soiling rate.
It works well if you are careful about which days to use:
- Use clean days only. Leave out days with a breakdown, a grid outage, a grid limit, a comms gap or a missing data file. Those days have their own losses that would distort the trend.
- Skip low-sun days. On heavily overcast days PR is noisy. Set a minimum daily irradiation.
- Correct for temperature. Hot days have lower PR anyway. Without a temperature correction, a cool spell after a hot one can look like the panels got cleaner.
- Use a robust fit. One hazy day can tilt an ordinary least-squares line. A robust method such as Theil-Sen, which takes the median of slopes between pairs of points, is much less sensitive to outliers.
- Log every cleaning. The method splits the data at each cleaning. If cleanings are not recorded, the stretches blur together.
3. A controlled cleaning test
Clean one block or one inverter's array, leave a similar one dirty, and compare their output per kWp over the next few clear days. It is a good way to confirm what the other methods say before changing a cleaning contract.
Turning the trend into kWh and money
Once you have a clean level (the PR just after a cleaning) and the trend line, the soiling loss on any day is:
Soiling kWh = (PR_clean − PR_trend) × H × P0
where H is that day's irradiation on the module plane in kWh/m² and P0 is the DC capacity in kWp. Multiply by the tariff to get the money lost. Sum over the days since the last cleaning to get the cost of the dirt so far.
Note the days with other events. The dust was on the panels on those days too, so they still carry a soiling loss. They just should not be used to fit the line.
When to clean
The decision is a trade-off between two costs:
- The cost of a cleaning cycle: labour, water (and its transport, if water is scarce), equipment or robot running costs, and any lost production while cleaning.
- The cost of not cleaning: the energy lost to soiling, which grows every day the panels stay dirty.
A practical rule: clean when the money lost to soiling since the last cleaning is about to exceed the cost of one cleaning cycle. Before that point, cleaning costs more than it recovers. After it, every day you wait costs more than the cleaning would.
A worked example
Made-up numbers to show the arithmetic.
| Item | Value |
|---|---|
| Plant size | 10,000 kWp |
| Average daily irradiation | 5.5 kWh/m² |
| Soiling rate from the PR trend | PR falls 0.2 points a day |
| Energy lost on day n after cleaning | 0.002 × n × 5.5 × 10,000 = 110 × n kWh |
| Cumulative loss after 20 days | 110 × (1 + 2 + … + 20) = 23,100 kWh |
| Value at an example tariff of 3 per kWh | 69,300 |
| Example cost of one cleaning cycle | 60,000 |
In this example the dirt has cost more than a cleaning by day 19. Cleaning every three weeks or so makes sense in this season. If the rate halves in the rainy months, the right interval gets much longer. The numbers are illustrative; your plant's rate, tariff and cleaning cost will be different.
Rain and forecasts
Heavy rain cleans modules for free, though light rain can turn dust into a film that sticks. If rain is forecast in the next few days, it can be worth waiting. After rain, check the PR: if it jumped back to the clean level, the rain did the job; if not, the dirt is cemented and needs a proper wash.
Cleaning without causing damage
A cleaning that scratches the glass costs more than the dirt it removed. A few general rules hold on most plants. Follow the module maker's cleaning guidance, because it can affect the warranty. Use soft brushes or cloths, not abrasive pads, so the anti-reflective coating is not worn away. Use water low in dissolved minerals where possible; hard water leaves spots that block light. Avoid splashing cold water on hot glass in the middle of a summer day; early morning or evening is safer and loses less production. Never stand or walk on modules. Record which rows were cleaned and when, so the PR trend can be split at the right day.
Contract cleaning cycles
Many O&M contracts specify a number of cleaning cycles per month. That protects the owner but ignores the weather. If you track the soiling loss, you can show the owner when an extra cycle would pay for itself, or when a cycle could be moved to a better week. Record every completed cycle against the contract either way; it is one of the first things an owner audits.
Things that look like soiling but are not
- A dirty irradiance sensor. If the pyranometer is dusty, measured sunlight falls and PR rises. That can hide plant soiling entirely. Clean sensors at least as often as modules.
- Degradation. Modules lose a little output every year. It does not recover after cleaning, which is how you tell it apart.
- Seasonal temperature. PR falls as summer comes. Temperature correction removes most of this.
- New shading. A growing tree or a new structure shows up at certain times of day, not evenly.
Where HKDataCrest Solar fits
HKDataCrest Solar finds soiling from each plant's own daily PR, using only clean days, temperature-corrected, split at every logged cleaning and fitted with a Theil-Sen line. When an open stretch keeps falling, it suggests a cleaning and values the dirt in kWh and money as "Dirty panels" in the loss breakdown. Cleaning cycles completed are tracked against the contract in the monthly report. Optimising the cleaning schedule against water and labour cost is something we build as a project; see AI for solar.